Bone Densitometry> XR-800>
Item Details
Click to enlarge
XR-800 (Reference ID:107)
Company name: Norland


Model:                   XR800

Table size:          
 8 foots.

Standard Scan Sites: 
AP Spine, Left and Right Hip, Forearm, Whole Bdy (Soft
                                          Tissue Composition and total Skeleton).

Optional scans:           
Research and small subjects.


NORLAND Table Specification

   AP Spine  Proximal Femur Forearm   Lateral Spine  Whole Body
 Scan Time  ~1 minute  1.5 minutes  3 minutes  <4 minutes  5 minutes
 In Vivio Precision  1%  1.4%  0.8%  2.4%  0.08%
 Line Resolution  1.5mm  1mm 1mm   1mm  6.5/13
 Point Resolution  1.5mm  1mm  1mm  1mm  2.8/7.8
 Scan Dose  3μSv  <15μSv  <15μSv 35μSv  0.2μSv 
 Accuracy           1% on Bone ND, 2% on fat and lean based on chemical standards


Specifications:

Scanner Description   Quickscan Pencil Beam Dual energy X-ray Absorptionmetry (DXA)
 Drive System  Stepper motors with Kevlar reinforced drive belts
 X-ray Source  Staionary anode X-ray tube oil and air coolong: 100kv constant potential, 1.3mA anode current, focal spot size:0.5mm
 Filtration  8 level automated samarium filtering (K-edge=46.8 keV) - minimum filtration is 2.7 mm aluminum equivalent
 X-ray Detectors  2 Nal scintillation detectors in plus counting equivalent
 Power  100-120 Vac; 220/230/240 Vac; 50/60 Hz; 700 VA maximum
 Operating temperature  15-32 C
 Relative Humidity  Up to 80% non-Condensing
 Table top size  2591mmx902mmx660mm (LxWxH)
 Weight  181Kg
 Active Scan Area  193cmx67.3cm
 Patient Marking  Laser Diode, red, Class II (FDA);  Class I (IEC); 
 Patient Positioning Aids  AP spine positioning block, hip sling with foot seperator, lateral positioning block, frearm  positioning fixture, scout scan, laser marking system
 Calibration  Daily calibiration varifies until is opening properly calibrated to a wedge phontom with 77 uniqe combination of bone and soft tissue provides clibertion for the widest range in body size in the industry.
 Computer  IBM compatibility Windows sotware pointing devise (mouse) ,keyboard,display,modem,network cared,saund sytem,DVD RW data bake up,calorprinte.
 Reference Database  Devided from phases 1 and 2 of NHANES   1988-1994 and Norland referance Sets(referto "referance Set Data Sheets for Central Bone Desitometer"document published by Norland )
 Quality Assurance  Assessment of an anatomicalphotom evaluates system accuracy and precision for bone,lean and fat measurement using Shewart Chart Analysis to confirm absolute and trending performance are within guidelines.

DOWNLOAD Catalogue
          XR-800.pdf
 
 
I_Open 0.36 T
I_open 0.4 Tesla
I_open 0.5 Tesla
EDGE PACS
RADION
TITUS
Phoneix
STREAM
MYSTIQ
iMagic
FOCUS
CGO-3000
CGO-2100
CGO-2100C
CRANEX BASEX
CRANEX Excel, Excel D
CRANEX D
CRANEX Novus
SCANORA 3D
CRANEX TOME
DIGORA PCT
DIGORA Optime
MINRAY
Fluoroscopy
Digital C-arm System
Mobile X-ray
Routine X-ray
Reguis 110
Reguis 190
Reguis 370
Reguis Console CS2
Reguis console CS3
DryPro873
DryPro793
DryPro832
XR-600
XR-800
EEG
EMG
PSG
IONM
2MP
3MP
5MP
X-ray Films
Fixer & Developer
Cassettes & Screens
Lead Apron
Spinal needles
Catheters
Electrodes
Disposable Cathaters
Cast
Medical Papers
Medical Gel
Surgical Blades
Username
Password


Registration
 
Polymedics Technology For Healthcare Developed by Hadeel.net